Especificaciones |
Instrument | Biometra TAdvanced 96/96 G
| Biometra TAdvanced 96 S/96 SG |
Capacity
|
96 x tubes 0.2 ml 96 well microplates 12 x strips 8 well
|
96 x tubes 0.2 ml 96 well microplates
|
Block
|
Aluminum
|
Silver
|
Block coating
|
Special Alloy
|
Gold
|
Block Exchange
|
Quick-X-Change
|
Quick-X-Change
|
Block Exchange time
|
less than 10s
|
less than 10s
|
Max. heating rate*
|
6,0 °C/sec
|
8.0 °C/sec.
|
Max. cooling rate*
|
4,0 °C/sec
|
5.5 °C/sec.
|
Avg. Heating Rate*
|
5,5 °C/sec
|
7.0 °C/sec.
|
Avg. Cooling Rate*
|
3,5 °C/sec
|
4.5 °C/sec.
|
Max./min. Gradient span1
|
30 °C/0.1 °C
|
40 °C/0.1 °C
|
Tª Uniformity
|
95 °C ± 0.60 °C after 15 s 70 °C ± 0.30 °C after 15 s 55 °C ± 0.20 °C after 15 s
|
95 °C ± 0.50 °C after 15 s 70 °C ± 0.25 °C after 15 s 55 °C ± 0.15 °C after 15 s
|
Gradient Tª Range1
|
20 °C to 99 °C
|
4 °C to 99 °C
|
Tª Range
|
3 °C to 99 °C
|
Control Accuracy
|
+/- 0.1 °C
|
Software
|
User specific quick start of the last five programs, program preview prior to start, toggle between spreadsheet and graphical programming mode, Linear Gradient Tool1, generate service info files (SINF),extended self-test, adjustable ramp rates, view gradient Tª graph1, PC control via Ethernet, comprehensive user administration tool with individual rights settings, Protocol Wizard
|
Display
|
7‘‘ Color Touchscreen
|
Auto restart after power failure
|
Yes
|
High Performance Smart Lid (HPSL) Technology
|
Yes
|
Lid Tª Range
|
30 °C to 110 °C
|
Power consumption
|
850 Watt
|
Power Supply
|
100, 115, 230 Volt, 50-60 Hz
|
Noise emission
|
Very low, max. 45 dB
|
Interfaces2
|
USB A, Ethernet
|
Working conditions
|
15 °C to 35 °C, 70 % air humidity, max. 2000 m NN
|
Dimensions (W x D x H)
|
277 mm x 457 mm x 264 mm
|
Dimensions (W x D x H) with lid opened
|
277 mm x 457 mm x 414 mm
|
Weight
|
15 kg
|
* measured inside the block
1 Only for model type “G” featuring gradient function
2 The network cable must be at least performance class Cat 5e and the cable configuration has to be STP
|
Instrument | Biometra TAdvanced 60/60 G
| Biometra TAdvanced 384/384 G |
Capacity
|
60 tubes 0.5 ml
|
384 well microplates
|
Block
|
Aluminum
|
Aluminum
|
Block coating
|
Special Alloy
|
Special Alloy
|
Block Exchange
|
Quick-X-Change
|
Quick-X-Change
|
Block Exchange time
|
less than 10s
|
less than 10s
|
Max. heating rate*
|
6.0 °C/sec
|
4.0 °C/sec
|
Max. cooling rate*
|
4.0 °C/sec
|
2.0 °C/sec
|
Avg. Heating Rate*
|
5.5 °C/sec
|
3.8 °C/sec
|
Avg. Cooling Rate*
|
3.0 °C/sec
|
1.7 °C/sec
|
Max./min. Gradient span1
|
30 °C
|
24°C
|
Tª Uniformity
|
95 °C ± 0.60 °C after 15s 70 °C ± 0.30 °C after 15s 55 °C ± 0.20 °C after 15s
|
95 °C ± 0.50 °C after 15s 70 °C ±0.25 °C after 15s 55 °C ± 0.15 °C after 15s
|
Gradient Tª Range1
|
20 °C to 99 °C
|
20 °C to 99 °C
|
Tª Range
|
3 °C to 99 °C
|
Control Accuracy
|
+/- 0.1 °C
|
Software
|
User specific quick start of the last five programs, program preview prior to start, toggle between spreadsheet and graphical programming mode, Linear Gradient Tool1, generate service info files (SINF),extended self-test, adjustable ramp rates, view gradient Tª graph1, PC control via Ethernet, comprehensive user administration tool with individual rights settings, Protocol Wizard
|
Display
|
7‘‘ Color Touchscreen
|
Auto restart after power failure
|
Yes
|
High Performance Smart Lid (HPSL) Technology
|
Yes
|
Lid Tª Range
|
30 °C to 110 °C
|
Power consumption
|
850 Watt
|
Power Supply
|
100, 115, 230 Volt, 50-60 Hz
|
Noise emission
|
Very low, max. 45 dB
|
Interfaces2
|
USB A, Ethernet
|
Working conditions
|
15 °C to 35 °C, 70 % air humidity, max. 2000 m NN
|
Dimensions (W x D x H)
|
277 mm x 457 mm x 264 mm
|
Dimensions (W x D x H) with lid opened
|
277 mm x 457 mm x 414 mm
|
Weight
|
15 kg
|
* measured inside the block
1 Only for model type “G” featuring gradient function
2 The network cable must be at least performance class Cat 5e and the cable configuration has to be STP
|
Instrument | Biometra TAdvanced Twin 48/48G | Biometra TAdvanced Twin 30 | Biometra TAdvanced Twin combi |
Capacity
|
2 x 48 x 0.2 ml tubes/ 2 x 48- well microtiter plate /2 x 6 x 8-well strips, 0.2 ml
|
2 x 30 x 0.5 ml tubes
|
2 x 48 x 0.2 ml tubes/ 2 x 6 x 8-well strips, 0.2 ml/2 x 48-well microtiter plate/ 2 x 18 x 0.5 ml tube
|
Block
|
Aluminum, special alloy
|
Aluminum, special alloy
|
Aluminum, special alloy
|
Max. heating rate1
|
5.2 °C/s
|
4.2 °C/s
|
3.1 °C/s
|
Max./min. gradient2
|
20 °C/0.1 °C in one block of the twin-block
|
-
|
-
|
Gradient Tª range2
|
20 °C to 99 °C in one block of the twin-block
|
|
|
Tª uniformity at 55 °C after 15 s
|
± 0.20 °C
|
± 0.20 °C
|
± 0.20 °C
|
Tª range
|
3 °C to 99 °C
|
3 °C to 99 °C
|
3 °C to 99 °C
|
Control accuracy
|
± 0.1 °C
|
± 0.1 °C
|
± 0.1 °C
|
Lid Tª range
|
30 °C to 110 °C
|
30 °C to 110 °C
|
30 °C to 110 °C
|
Program memory
|
350 programs in up to 90 user directories
|
350 programs in up to 90 user directories
|
350 programs in up to 90 user directories
|
Dimensions (W x D x H, mm)
|
277 x 457 x 264
|
277 x 457 x 264
|
277 x 457 x 264
|
G = with gradient function 1 measured within sample block 2 applies only to cycler models with gradient function For more technical details please refer to the corresponding Technical Data sheets.
|
|
Caracteristicas |
Biometra TAdvanced – the high-performance thermal cycler for DNA amplification by PCR
- Twelve different sample blocks: including a 96-well silver block as high-end variant
- Powerful control electronics: Now even an aluminum block reaches superior heating and cooling rates as usually only achieved in instruments with silver block
- Fastest Ramping, Highest Accuracy and Intelligent Block/Well Control (RAC): high temperature uniformity and maximum reproducibility, no over- or undershooting of the programmed target temperature
- Optional with gradient: simple optimization of new primer pairs
- Linear Gradient Tool (LGT): specific adjustment of the gradient temperature profile
- High Performance Smart Lid Technology (HPSL): fast heating, constant contact pressure and easy use
- Quick Block Exchange System: easy, fast exchange of sample blocks
- Whisper Quiet Technology: particularly quiet operation with a maximum noise level of 45 dB
- Intuitive software: graphical programming and Easy Spreasheet Programming
- Multi Step Programming: easy creation of PCR protocols during programming without the need to toggle between different windows
- Advanced User Management (AUM): flexible user management with individual assignment of user rights for single users
- User Specific Quick Start: no tedious searching of already used PCR programs due to the combination of Quick Start and Program Preview
- Extended Self Test: automatic system diagnosis and documentation of PCR runs
- Comfortable 7 inch color touch display
- USB and Ethernet port
- Protocol Wizard: Automatic creation of PCR protocols with few inputs
|